Control of Strobilurin Fungicides in Wheat Using Direct Analysis in Real Time Accurate Time-of-Flight and Desorption Electrospray Ionization Linear Ion Trap Mass Spectrometry

Ambient mass spectrometry has been used for the analysis of strobilurin residues in wheat. The use of this novel, challenging technique, employing a direct analysis in a real time (DART) ion-source coupled with a time-of-flight mass spectrometer (TOF MS) and a desorption electrospray ionization (DESI) source coupled with a linear ion trap tandem MS (LIT MS (n)), permitted a direct screen of the occurrence of target fungicides in treated grains in less than 1 min. For quantification purpose by DART-TOF MS, an ethyl acetate extract had to be prepared. With the use of a prochloraz as an internal standard, the performance characteristics obtained by repeated analyses of extract, spiked at 50 µg kg(-1) with six strobilurins (azoxystrobin, picoxystrobin, dimoxystrobin, kresoxim-methyl, pyraclostrobin, and trifloxystrobin), were in the following range: recoveries 78–92 %, repeatability (RSD) 8–15 %, linearity (R (2)) 0.9900–0.9978. The analysis of wheat with incurred strobilurin residues demonstrated good trueness of data generated by the DART-TOF MS method; the results were in a good agreement with those obtained by the conventional approach, i.e., by the QuEChERS sample handling procedure followed by identification/quantification employing high-performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Tandem mass spectrometry using DESI-LIT MS (n) provided a sufficient number of product ions for confirmation of the identity of azoxystrobin and pyraclostrobin in incurred wheat samples.

Schurek J, Vaclavik L, et al.; 2008; Anal Chem